产品 包装化妆航空 RDDC

媒体

RDDC
RDDC
RDDC without ERM
RDDC with ERM
RDDC with ERM
RDDC with ERM
Energy Recovery Module
Energy Recovery Module
Energy Recovery Module
Energy Recovery Module
Hail Guard


描述

Reznor's RDDC (MAPS®IV) packaged rooftop units are designed to cool, dehumidify, and heat high volumes of outside air year round for makeup air and ventilation applications.  MAPSIV can provide significant capacities of space conditioning.  The MAPS IV series all leverage the use of modulating scroll compressor technology to maintain desired leaving conditions.

Model RDDC units offer all these same features, but also include Reznor Re-Heat Pump™ dedicated reheat cycle. Re-heating of the air by this method saves over 4 to 5 times the energy used by electric heating elements. Additionally, the system is capable of maintaining reheat even when the demand for cooling and dehumidification is minimal.

Complies with ASHRAE Standard 90.1.

All MAPSIV products feature the Reznor IQ digital controller to fully integrate all operation and external sensing into a stand-alone package or through native BacNet, into a building management system.

暖气范围 ( MBH )

冷却范围 ( MBH )

气流范围 ( CFM )

热效率 在满负荷 ( Gross )

Standard

Supply Fan

  • 1,000 - 9,000 CFM
  • Forward Curve Blowers
  • Belt Driven, Adjustable Sheave System
  • Vertical Discharge
  • Vibration Isolated Fan and Motor System
  • Fan and Motor Lube Lines for Servicing


Mechanical Cooling

  • R410A Refrigerant (Environmentally Friendly)
  • High Outside Air Applications
  • 10% - 100% Capacity Control
  • Modulated Capacity Scroll Compressor with internal motor overload
  • Compressor Anti-Cycle Programming
  • Mechanical Gauge Connections
  • Fully Interlaced Coils

Dedicated Reheat Pump

  • Independent Reheat System
    • Verifiable & Predictable Performance
    • Low ambient operation (58°F)
    • Lower energy cost
  • R410-A Refrigerant

Gas Heating

  • A Minimum of 80% Gas Efficiency throughout Variable Speed Venter - Burner Modulation
  • High Turn Down Ratio (Modulation)
    • Up to 8:1 (12.5-100%)
  • 409 Stainless Steel Heat Exchanger for 100°F Temperature Rise (Optional 316 Stainless Steel)
  • Isolated Combustion Air Intake
  • Built-in Failure Alarm Diagnostics
  • Standard Gas Pressure Safeties

Construction

  • Double Wall Construction Standard - R7 or higher value
  • Hinged Access Doors with Handles
  • Easy Access Compressor Section
  • Filters (MERV8 minimum)
  • Slide out and Sloped Stainless Steel Condensate Drain Pan
  • 4 - 6 Point Base Lifting Connections
  • G90 Galvanized Steel Substrate, 60 Gloss Finish
  • Hold Door Open Service Hinges

Controls

  • Isolated High Voltage Compartment
  • Controller Output LED Status
  • Test Mode
  • Field Selectable Unit Configuration and Unit Mounted Display

Warranty

  • Standard one (1) Year Parts Warranty

 


OPTIONS

Gas Heating

  • Natural Gas or Propane

Supply Fan

  • 1,000 - 9,000 CFM
  • Horizontal Curb Option
  • Optional Unit or Field Mounted VFD
    • Duct Static Pressure Control
    • CO2 Control
    • Building Static Pressure Control
  • Power Exhaust

Mechanical Cooling

  • Protective Coil Coatings

Intake

  • 100% Outside Air Option
  • 100% Outside & Return Air Option
    • Economizer control
    • CO2 Control
    • Building Static Pressure Control
    • Manual Positioning External 0-10V Signal
  • Optional Outside Air Hood with Washable 1” Filter
  • Integral Energy Recovery Option
    • Variable Flow Control
    • Frost Control
    • Single Curb
    • Isolation Dampers

Dedicated Reheat Pump

  • Optional Modulating control for tighter performance

Controls

  • Voltages: 208/3, 230/3, 460/3, 575/3
  • Optional Remote User Display
  • Optional Phase Loss, Smoke Detector, Filter Status
  • Optional Weatherproof Convenience Power Outlet

Construction

  • Unit or Field Mounted Disconnects
  • 2” or 4” Permanent or Pleated Filters (MERV8 or MERV13 available)
  • Hail Guard
  • Insulated, 16 Gauge, Downturn or Horizontal air Flow, Full Perimeter Curb

Warranty Options

  • Optional Five (5) Year Compressor Warranty

 


宣传册
4 文件

宣传册


English
Heating/Cooling Makeup Air Unit Marketing Catalog
Heating/Cooling Makeup Air Unit Marketing Catalog
下载文件
754.3 kB
Comp Edge: The advantages of using MAPS units
Competitive Edge: The advantages of using MAPS units in different environments and the range of configurations for any zone
下载文件
408.7 kB
Support Edge: Reznor MAPS equipment start-up assistance
Support Edge: Reznor MAPS equipment start-up assistance
下载文件
305.1 kB
Heating, Cooling, Ventilation & VRF Product Line
Heating, Cooling, Ventilation & VRF Product Line Sheet
下载文件
630.7 kB

技术数据
2 文件

技术数据


English
Catalog - MAPS®
Modular Air Procesing System (MAPS) catalog for MAPS-III & MAPS- IV Series
下载文件
5.3 MB
Sample Specs - MAPS®
Sample specifications for Modular Air Processing System (MAPS) Series (Word document)
下载文件
174.5 kB

服务和安装
13 文件

服务和安装


English
Unit Installation Manual - MAPSIII & MAPSIV
Installation manual for Models RCB, RDB, RCC, RDC, RDCB, RDDB, RDCC, RDDC, RECB, REDB, RECC, & REDC
下载文件
8.9 MB
Parts Manuals - MAPSIII&IV
Parts manual for MAPSIII (Models RCB, RDB, RDCB, RDDB, RECB, & REDB) & MAPSIV (Models RCC, RDC, RDCC, RDDC, RECC, & REDC)
下载文件
16.2 MB
Option - Installation - Energy Recovery Module Installation - MAPS III & IV
Instructions for installing an energy recovery module on a MAPS III or MAPS IV system
下载文件
1.6 MB
Option - Installation - Weather Hood Assembly
Instructions for installing a weather hood for Models ADF, ADFH, RCB, RDB, RDCB, RDDB, RECB, REDB, RCC, RDC, RDCC, RDDC, RECC, REDC, RPB, RPBL, RBL, YDHA, YDMA, and YDSA
下载文件
814.5 kB
Option RB5 - Installation - Remote Display
Installation instructions for optional remote mounted display for PreevA & MAPS Series, and Model ZQYRA
下载文件
335.8 kB
Option - Installation - Roof Curbs Assembly
Instructions for installing roof curb for various models
下载文件
1.6 MB
Conversion Info - Vent Extension - MAPS III & IV Series
Gas heating vent extension for Models RDCB, RDDB, RDCC, & RDDC
下载文件
344.6 kB
Controls - D19, D21, and D22 Control Manual
Air handler system control options D19, D21, and D22
下载文件
1.2 MB
Parts Manuals - Replacement Ignition System and Gas Valves
Replacement ignition system and gas valves by serial number code and Maxitrol system components by serial number suffix
下载文件
1.3 MB
Field Service - Damper Motor Replacement
Instructions for replacement kit (261697) for Belimo damper motor
下载文件
161.8 kB
Operation - MAPS - A,B,C
Operation, maintenance and service manual for MAPSIII & MAPS IV units in cabinet sizes A, B, & C for Models RCB, RDB, RDCB, RDDB, RECB, REDB, RCC, RDC, RDCC, RDDC, RECC, REDC
下载文件
6.0 MB
Controls - IQ System Technical Guide - MAPSIII & IV
IQ system technical guide for control options D15, D16, D17, & D18 for Models RCB, RDB, RDCB, RDDB, RECB, & REDB manufactured since March of 2010 (Serial number code BJC and higher), and for Models RCC, RDC, RDCC, RDDC, RECC, & REDC - Applies to IQ Controller with Version 2 Software
下载文件
1.7 MB
Field Service - Replacement of Discontinued Relays
Installation for kits designed to replace relays no longer available from suppliers. Applies to all Reznor units using obsolete relays.
下载文件
340.4 kB

其他文件
1 文件

其他文件


English
Warranty Statement
Reznor equipment limited warranty statement
下载文件
183.4 kB