Продукты обработки воздуха SSCBL

Мультимедиа

SSCBL
SSCBL
SSCBL
SSCBL
SSCBL
SSCBL


Описание

Reznor's SSCBL is a unified assembly of one, two or three separated-combustion duct furnaces and a large-capacity blower cabinet.

Sizes are available with heating capacities from 400,000 through 1,200,000 BTUH gas input.  The standard packages are heating-only systems, but factory-installed gas and inlet-air control options are available to meet makeup air or combination heating/makeup air specifications.  These systems are designed for indoor installation in areas with negative pressure and/or extremely dirty or mildly corrosive atmospheres.  All furnaces are at least 80% thermal efficient.  Model SSCBL is available for use with either natural or propane gas as specified.  All units are equipped with required limit and safety controls.

Both the separated-combustion duct furnaces and the packaged system are design-certified by the Canadian Standards Association for installation in the U.S. and Canada.

Отопление Диапазон ( MBH )

Диапазон охлаждения ( MBH )

Диапазон расхода воздуха ( CFM )

Тепловая эффективность (при полной нагрузке) ( Gross )

Standard

  • Orifices for natural gas
  • Aluminized steel heat exchanger (when inlet air temperature is below 40°F or temperature rise is less than 40°F, optional stainless steel heat exchanger is recommended.)
  • Aluminized burners with a stainless steel insert
  • 208-volt power supply
  • 24-volt control transformer
  • Redundant single-stage combination gas valve
  • Intermittent spark safety pilot with electronic flame supervision
  • Fan and limit safety controls
  • Pre-wired to terminal blocks
  • Twin centrifugal blowers with adjustable belt drive
  • Galvalume steel cabinet with interlocking joint construction
  • Horizontal discharge air opening with duct flanges
  • Curb cap base with hangers for suspension
  • Blower cabinet (less optional insulation, filter rack and filters) with horizontal inlet-air opening
  • Left side controls (facing air stream)
  • 1/2" O.D. BX cable (Chicago code)

Optional Features - Factory Installed

  • Unit equipped for propane gas
  • E-3 (409) stainless steel heat exchanger
  • 321 stainless steel heat exchanger
  • E-3 (409) stainless steel burners
  • E-3 (409) stainless steel drip pan
  • Intermittent spark safety pilot with timed lockout
  • Individual single-stage gas control on each furnace section
  • Two-stage gas control on each furnace section - effective 2 to 6 stage gas control (see Gas Control Option section of printed catalog for more detailed description)
  • Electronic modulation 50%-100% turndown or 20%-100% turndown
  • Variable frequency drive with open dripproof or totally enclosed motor
  • VFD  control options
    • Soft start
    • two speed control
    • DDC signal from remote device
  • Makeup air controls/dampers
  • 208/1, 230/1, 208/3, 230/3, 460/3, 575/3 supply voltages
  • 1 HP through 20 HP open drip-proof or totally enclosed motors available (motors meet EISA specifications for efficiency)
  • Burner air shutters (required for units equipped for propane gas)
  • Firestat(s)
  • Freezestat(s)
  • Convenience outlet
  • 1/2" O.D. BX cable (Chicago code)
  • Motor starter (optional with motors having internal overload protection)
  • Downturn plenum (insulated)
  • Discharge damper, 2 position with downturn plenum
  • Blower cabinet insulation
  • Filter rack with 2" disposable, pleated or permanent filters
  • Double wall cabinet construction
  • FM, GAP manifold arrangements
  • High ambient burner cutoff
  • Gas pressure safety switches
  • Air flow proving switch
  • Right side controls (facing airstream)
  • Cooling coil cabinet with DX or chilled water coil requires special handling
  • Extended warranty on heat exchanger(s); five (5) or ten (10) years

Optional Features - Field Installed

  • Horizontal or vertical combustion-air inlet/vent terminal assembly (one per furnace section; installation requirement)
  • Remote control center
  • Disconnect switch - UL listed
  • Single-stage thermostat
  • Two-stage thermostat
  • Electronic 7-day programmable thermostat
  • Cooling coil cabinet with DX or chilled water coil (See RGBL in packaged heating outdoor category)
  • Evaporative cooling module (see evaporative cooling catalog section)

 


брошюры
2 Файлы

брошюры


English
Large Capacity Heater Marketing Catalog
Large Capacity Heater Marketing Catalog
скачать файл
940.5 kB
Heating, Cooling, Ventilation & VRF Product Line
Heating, Cooling, Ventilation & VRF Product Line Sheet
скачать файл
607.6 kB

технические данные
1 Файл

технические данные


English
Catalog - Air Handler
Commcial air handler catalog for Models SSCBL, RPBL, & RBL
скачать файл
2.1 MB

Услуги / Монтаж
24 Файлы

Услуги / Монтаж


English
Unit Installation Manual - SSCBL & RPBL
Installation manual for Model SSCBL & RPBL
скачать файл
1.9 MB
Parts Manuals - Separated Combustion - Parts Manual
Parts manual for Models SC & SSCBL
скачать файл
2.1 MB
Field Service - Replacement Venter Motor and Mounting Plate
Instructions for assembling replacement venter motor and motor mounting plate for Models RP, RPB, RPBL, SC, & SSCBL
скачать файл
361.6 kB
Option - Installation - Vent/Combustion Air Kits Installation
Instructions for installing vertical or horizontal vent/combustion air kits for separated combustion
скачать файл
304.5 kB
Field Service - Replacement Gear Motor Kit
Instructions for installing replacement gear motor kit for Models SC, SSCBL, HRPD, RP, RPB & RPBL
скачать файл
755.5 kB
Option - Installation - Evaporative Cooling Option
Instructions for installing evaporative cooling module as an option
скачать файл
1.1 MB
Parts Manuals - Functional Replacement Fan/Blower Controls and Limit Controls
 Parts manual for functional replacement fan/blower controls and limit controls
скачать файл
322.8 kB
Controls - D19, D21, and D22 Control Manual
Air handler system control options D19, D21, and D22
скачать файл
1.2 MB
Parts Manuals - Replacement Ignition System and Gas Valves
Replacement ignition system and gas valves by serial number code and Maxitrol system components by serial number suffix
скачать файл
1.3 MB
Parts Manuals - Pilots - Parts manual
Functional replacement pilots
скачать файл
394.4 kB
Option - Installation - Gas Pressure Regulator Kit Installation
Instructions for installing a gas pressure regulator kit
скачать файл
251.3 kB
Conversion Info - Gas Conversion - Various Models
Gas conversion parts and instructions for various Reznor units
скачать файл
1.5 MB
Field Service - Replacement Pressure Switch Kits
Replacement pressure switch kits for Models ADF, ADFH, RDF, SC, SSCBL,  and to Models RP, RPB, & RPBL manufactured in 1991 or later
скачать файл
374.7 kB
Field Service - Replacment Relay Kit - PN 262375
Replacement relay kit for Reznor part number 262375, applies to all power vented units using Reznor part number 206146 time delay relay
скачать файл
1.2 MB
Option - Installation - Valve Kit - M6
Replacement kit for natural gas valve with code M6
скачать файл
120.5 kB
Field Service - Damper Motor Replacement Kit
Replacement kit for discontinued damper motors
скачать файл
440.0 kB
Field Service - Replacement Relay Kit - PN 259521
Replacement relay kit for Reznor part number 259521 - applies to power vented units using Reznor part number 46233 or 259518 time delay relay
скачать файл
646.2 kB
Option - Installation - Replacement Door Latch Kit
Replacement door latch kit for Models RPB, RPBL, SSCBL, ADF, ADFH, & RBL
скачать файл
149.0 kB
Field Service - Ignition Control Replacement - Various Models
Ignition control replacement kit for pilot code 62, 63, 65, 66, & 84 (found in first set of digitis of serial number)
скачать файл
250.4 kB
Option - Installation - Replacement for Discontinued Fan Control
Replacement kit for discontinued fan control, applies to duct furnaces and air handling systems with a Thermocore® heat exchanger
скачать файл
368.5 kB
Option - Installation - Replacement Venter Post Purge Control
Replacement kit for discontinued venter post purge control - applies to Reznor power vented/separated combustion furnaces and air handlers manufactured before 1987
скачать файл
221.3 kB
Field Service - Repl Kits for Amplifier in Electronic Modulation
Replacement kits for Maxitrol Amplifier Options AG7, AG8, AG9
скачать файл
293.8 kB
Field Service - Replacement of Discontinued Relays
Installation for kits designed to replace relays no longer available from suppliers. Applies to all Reznor units using obsolete relays.
скачать файл
340.4 kB
Français
Instructions D'Installation - Modèle SSCBL et RPBL
Installation, fonctionnement et entretien concerne les systèmes de modèles SSCBL et RPBL
скачать файл
3.3 MB

Другие файлы
1 Файл

Другие файлы


English
Warranty Statement
Reznor equipment limited warranty statement
скачать файл
183.4 kB