Producten Gecombineerde ventilatie RDDC

Media

RDDC
RDDC
RDDC without ERM
RDDC with ERM
RDDC with ERM
RDDC with ERM
Energy Recovery Module
Energy Recovery Module
Energy Recovery Module
Energy Recovery Module
Hail Guard


Beschrijving

Reznor's RDDC (MAPS®IV) packaged rooftop units are designed to cool, dehumidify, and heat high volumes of outside air year round for makeup air and ventilation applications.  MAPSIV can provide significant capacities of space conditioning.  The MAPS IV series all leverage the use of modulating scroll compressor technology to maintain desired leaving conditions.

Model RDDC units offer all these same features, but also include Reznor Re-Heat Pump™ dedicated reheat cycle. Re-heating of the air by this method saves over 4 to 5 times the energy used by electric heating elements. Additionally, the system is capable of maintaining reheat even when the demand for cooling and dehumidification is minimal.

Complies with ASHRAE Standard 90.1.

All MAPSIV products feature the Reznor IQ digital controller to fully integrate all operation and external sensing into a stand-alone package or through native BacNet, into a building management system.

Verwarmingscapaciteit ( MBH )

Koelcapaciteit ( MBH )

Luchtdebiet ( CFM )

Rendement bij vollast ( BW )

Standard

Supply Fan

  • 1,000 - 9,000 CFM
  • Forward Curve Blowers
  • Belt Driven, Adjustable Sheave System
  • Vertical Discharge
  • Vibration Isolated Fan and Motor System
  • Fan and Motor Lube Lines for Servicing


Mechanical Cooling

  • R410A Refrigerant (Environmentally Friendly)
  • High Outside Air Applications
  • 10% - 100% Capacity Control
  • Modulated Capacity Scroll Compressor with internal motor overload
  • Compressor Anti-Cycle Programming
  • Mechanical Gauge Connections
  • Fully Interlaced Coils

Dedicated Reheat Pump

  • Independent Reheat System
    • Verifiable & Predictable Performance
    • Low ambient operation (58°F)
    • Lower energy cost
  • R410-A Refrigerant

Gas Heating

  • A Minimum of 80% Gas Efficiency throughout Variable Speed Venter - Burner Modulation
  • High Turn Down Ratio (Modulation)
    • Up to 8:1 (12.5-100%)
  • 409 Stainless Steel Heat Exchanger for 100°F Temperature Rise (Optional 316 Stainless Steel)
  • Isolated Combustion Air Intake
  • Built-in Failure Alarm Diagnostics
  • Standard Gas Pressure Safeties

Construction

  • Double Wall Construction Standard - R7 or higher value
  • Hinged Access Doors with Handles
  • Easy Access Compressor Section
  • Filters (MERV8 minimum)
  • Slide out and Sloped Stainless Steel Condensate Drain Pan
  • 4 - 6 Point Base Lifting Connections
  • G90 Galvanized Steel Substrate, 60 Gloss Finish
  • Hold Door Open Service Hinges

Controls

  • Isolated High Voltage Compartment
  • Controller Output LED Status
  • Test Mode
  • Field Selectable Unit Configuration and Unit Mounted Display

Warranty

  • Standard one (1) Year Parts Warranty

 


OPTIONS

Gas Heating

  • Natural Gas or Propane

Supply Fan

  • 1,000 - 9,000 CFM
  • Horizontal Curb Option
  • Optional Unit or Field Mounted VFD
    • Duct Static Pressure Control
    • CO2 Control
    • Building Static Pressure Control
  • Power Exhaust

Mechanical Cooling

  • Protective Coil Coatings

Intake

  • 100% Outside Air Option
  • 100% Outside & Return Air Option
    • Economizer control
    • CO2 Control
    • Building Static Pressure Control
    • Manual Positioning External 0-10V Signal
  • Optional Outside Air Hood with Washable 1” Filter
  • Integral Energy Recovery Option
    • Variable Flow Control
    • Frost Control
    • Single Curb
    • Isolation Dampers

Dedicated Reheat Pump

  • Optional Modulating control for tighter performance

Controls

  • Voltages: 208/3, 230/3, 460/3, 575/3
  • Optional Remote User Display
  • Optional Phase Loss, Smoke Detector, Filter Status
  • Optional Weatherproof Convenience Power Outlet

Construction

  • Unit or Field Mounted Disconnects
  • 2” or 4” Permanent or Pleated Filters (MERV8 or MERV13 available)
  • Hail Guard
  • Insulated, 16 Gauge, Downturn or Horizontal air Flow, Full Perimeter Curb

Warranty Options

  • Optional Five (5) Year Compressor Warranty

 


Brochures
4 Bestanden

Brochures


English
Heating/Cooling Makeup Air Unit Marketing Catalog
Heating/Cooling Makeup Air Unit Marketing Catalog
Bestand downloaden
754.3 kB
Comp Edge: The advantages of using MAPS units
Competitive Edge: The advantages of using MAPS units in different environments and the range of configurations for any zone
Bestand downloaden
408.7 kB
Support Edge: Reznor MAPS equipment start-up assistance
Support Edge: Reznor MAPS equipment start-up assistance
Bestand downloaden
305.1 kB
Heating, Cooling, Ventilation & VRF Product Line
Heating, Cooling, Ventilation & VRF Product Line Sheet
Bestand downloaden
630.7 kB

Technische Gegevens
2 Bestanden

Technische Gegevens


English
Catalog - MAPS®
Modular Air Procesing System (MAPS) catalog for MAPS-III & MAPS- IV Series
Bestand downloaden
5.3 MB
Sample Specs - MAPS®
Sample specifications for Modular Air Processing System (MAPS) Series (Word document)
Bestand downloaden
174.5 kB

Onderhoud / Installatie
13 Bestanden

Onderhoud / Installatie


English
Unit Installation Manual - MAPSIII & MAPSIV
Installation manual for Models RCB, RDB, RCC, RDC, RDCB, RDDB, RDCC, RDDC, RECB, REDB, RECC, & REDC
Bestand downloaden
8.9 MB
Parts Manuals - MAPSIII&IV
Parts manual for MAPSIII (Models RCB, RDB, RDCB, RDDB, RECB, & REDB) & MAPSIV (Models RCC, RDC, RDCC, RDDC, RECC, & REDC)
Bestand downloaden
16.2 MB
Option - Installation - Energy Recovery Module Installation - MAPS III & IV
Instructions for installing an energy recovery module on a MAPS III or MAPS IV system
Bestand downloaden
1.6 MB
Conversion Info - Vent Extension - MAPS III & IV Series
Gas heating vent extension for Models RDCB, RDDB, RDCC, & RDDC
Bestand downloaden
344.6 kB
Option - Installation - Roof Curbs Assembly
Instructions for installing roof curb for various models
Bestand downloaden
1.6 MB
Option - Installation - Weather Hood Assembly
Instructions for installing a weather hood for Models ADF, ADFH, RCB, RDB, RDCB, RDDB, RECB, REDB, RCC, RDC, RDCC, RDDC, RECC, REDC, RPB, RPBL, RBL, YDHA, YDMA, and YDSA
Bestand downloaden
814.5 kB
Option RB5 - Installation - Remote Display
Installation instructions for optional remote mounted display for PreevA & MAPS Series, and Model ZQYRA
Bestand downloaden
335.8 kB
Controls - D19, D21, and D22 Control Manual
Air handler system control options D19, D21, and D22
Bestand downloaden
1.2 MB
Parts Manuals - Replacement Ignition System and Gas Valves
Replacement ignition system and gas valves by serial number code and Maxitrol system components by serial number suffix
Bestand downloaden
1.3 MB
Controls - IQ System Technical Guide - MAPSIII & IV
IQ system technical guide for control options D15, D16, D17, & D18 for Models RCB, RDB, RDCB, RDDB, RECB, & REDB manufactured since March of 2010 (Serial number code BJC and higher), and for Models RCC, RDC, RDCC, RDDC, RECC, & REDC - Applies to IQ Controller with Version 2 Software
Bestand downloaden
1.7 MB
Operation - MAPS - A,B,C
Operation, maintenance and service manual for MAPSIII & MAPS IV units in cabinet sizes A, B, & C for Models RCB, RDB, RDCB, RDDB, RECB, REDB, RCC, RDC, RDCC, RDDC, RECC, REDC
Bestand downloaden
6.0 MB
Field Service - Damper Motor Replacement
Instructions for replacement kit (261697) for Belimo damper motor
Bestand downloaden
161.8 kB
Field Service - Replacement of Discontinued Relays
Installation for kits designed to replace relays no longer available from suppliers. Applies to all Reznor units using obsolete relays.
Bestand downloaden
340.4 kB

Andere Bestanden
1 Bestand

Andere Bestanden


English
Warranty Statement
Reznor equipment limited warranty statement
Bestand downloaden
183.4 kB